Visitation Academy - Terrace & Window Repairs

A renovation at a two-story private school included repairs to a second-floor terrace and the masonry tied to it, where water had been getting through. The cause had to be established before a repair could be specified, since terrace waterproofing failures often trace to detailing at transitions and penetrations rather than the membrane field. A site visit and review of existing reports, including a structural engineer’s findings on the terrace, supported a written opinion on the source and the corrective work.

The engagement then moved into design assist and construction. Development details and product recommendations went to the design team for the repair documents, followed by progress observations and Electronic Leak Detection testing of the new terrace membrane before the topping slab was placed. The window replacement scope added spray-nozzle watertightness testing to AAMA 501.2.

Location:
St. Louis, MO

Client Type:
Owner

Size:
2-story

Market:
Education

OUR APPROACH

Source Investigation

Site visit and existing report review to establish the leak cause

Written Opinion

Findings and corrective work documented for the design team

Design Assist

Repair details and product recommendations issued for the documents

Membrane Testing

Electronic Leak Detection of the new terrace before the topping slab

Window Testing

Spray-nozzle watertightness verified on the replacement scope

METHODS & STANDARDS

Electronic Leak Detection

New terrace membrane integrity verified before topping slab

AAMA 501.2

Spray-nozzle watertightness confirmed on replacement windows

Forensic Investigation

Leak source established before repair was specified

Progress Observation

Installed repair work reviewed in the field